Icom IC-9700
DH7LK, Lutz, email see qrz.com
under validation
Version: V1.0
Date: 27. June 2020
For Fldigi 4.1.13 or higher
Default Adress for IC9700: A2
DATA Mode in SETMODE as preferred digi mode
Frequency range 144MHz to 1.3GHz
Defaults 9600Bd/2Stop, Retries 4
At startup:
Save the VFO A status to Memory 99.
Set rig into conditions for digi modes:
Data Mode, AGC Fast, no frequency response limitation.
Switch OFF Noise reduction, Notch and Noise Blanker.
At Shutdown:
Bring the rig back to normal SSB voice operation and
recall the VFO A status from Memory 99.
Feel free to adapt to your personal needs. If you change,
don't forget to adapt the "size" to the actual # of bytes!
RigCAT - IC-9700
160
4
80
9600
2
false
false
true
INIT
117
FE FE A2 E0 07 D0 FD
FE FE A2 E0 07 00 FD
FE FE A2 E0 08 00 99 FD
FE FE A2 E0 09 FD
FE FE A2 E0 1A 05 00 57 03 FD
FE FE A2 E0 01 01 FD
FE FE A2 E0 1A 06 01 01 FD
FE FE A2 E0 16 12 01 FD
FE FE A2 E0 07 D1 FD
FE FE A2 E0 1A 06 01 01 FD
FE FE A2 E0 07 D0 FD
FE FE A2 E0 16 41 00 FD
FE FE A2 E0 16 22 00 FD
FE FE A2 E0 16 48 00 FD
FE FE A2 E0 16 40 00 FD
CLOSE
22
FE FE A2 E0 08 00 99 FD
FE FE A2 E0 0A FD
FE FE A2 E0 16 12 03 FD
OK
6
FE FE 00 A2
FB
FD
BAD
6
FE FE 00 A2
FA
FD
D-USB
01
D-LSB
00
RTTY
04
RTTY-R
08
CW
03
CW-R
07
D-FM
05
DV
17
D-AM
02
D-LSB
RTTY
CW
50
00
100
01
150
02
200
03
250
04
300
05
350
06
400
07
450
08
500
09
600
10
700
11
800
12
900
13
1000
14
1100
15
1200
16
1300
17
1400
18
1500
19
1600
20
1700
21
1800
22
1900
23
2000
24
2100
25
2200
26
2300
27
2400
28
2500
29
2600
30
2700
31
2800
32
2900
33
3000
34
3100
35
3200
36
3300
37
3400
38
3500
39
3600
40
SETMODE
17
FE FE A2 00
06
BINARY
1
FD
FE FE A2 E0 1A 06 01 01 FD
OK
BAD
GETMODE
6
FE FE A2 00
04
FD
MODE
MODE
8
FE FE 00 A2
04
BINARY
1
1
FD
SETBW
8
FE FE A2 00
1A 03
BINARY
1
FD
OK
BAD
GETBW
7
FE FE A2 00
1A 03
FD
BW
BW
8
FE FE 00 A2
1A 03
BINARY
1
FD
0,0; 255,100
GET_SMETER
7
FE FE A2 00 15 02 FD
SMETER
SMETER
9
FE FE 00 A2 15 02
BCD
4
255
0
1
FD
0,0;255,100
GET_PWRMETER
7
FE FE A2 00 15 11 FD
PWRMETER
PWRMETER
9
FE FE 00 A2 15 11
BCD
4
255
0
1
FD
0,0; 256,100;
SET_PWRLEVEL
8
FE FE A2 00 14 0A
BCD
4
FD
GET_PWRLEVEL
7
FE FE A2 00 15 11 FD
PWRLEVEL
PWRLEVEL
9
FE FE 00 A2 15 11
BCD
4
255
0
1
FD
SETFREQ
11
FE FE A2 00
05
BCD
10
1300000000
144000000
1
true
FD
OK
BAD
GETFREQ
6
FE FE A2 00
03
FD
FREQ
FREQ
11
FE FE 00 A2
03
BCD
10
1300000000
144000000
1
true
FD
73,400; 208,3100;
SET_NOTCH_ON
8
FE FE A2 00 16 48 01 FD
SET_NOTCH_OFF
8
FE FE A2 00 16 48 00 FD
SET_NOTCH_VAL
8
FE FE A2 00 14 0D
BCD
4
FD
NOTCH_ON
8
FE FE 00 A2 16 48 01 FD
GET_NOTCH_ON
7
FE FE A2 00 16 48 FD
NOTCH_ON
NOTCH
9
FE FE 00 A2 14 0D
BCD
4
FD
GET_NOTCH
7
FE FE A2 00 14 0D FD
NOTCH
PTTON
8
FE FE A2 00
1C 00 01
FD
OK
BAD
PTTOFF
8
FE FE A2 00
1C 00 00
FD
OK
BAD